手机 / 微信: 17821719638 | 电话: 021-37785053 | 邮箱: zepengtech@163.com | 中文 英文 |
![]() |
专业销售精密调压阀|电动减压阀|电气转换器|继动器|流量放大器|康气通Controlairlnc | ![]() |
---|
首 页 | | | 新闻动态 | | | 公司介绍 | | | 产品中心 | | | 项目案例 | | | 联系我们 | | | 营业执照 |
---|
ControlAir 500X 型将电流或电压输入信号转换为线性比例的气动输出压力。这款多功能仪器专为需要高可靠性和可重复性且经济的控制应用而设计。 TYPE500X 型有两种不同的版本。低量程型号专为标准过程控制应用而设计,通常使用 3 至 15 psig(0.2 至 1 bar)的输出。扩展范围装置提供高达 145 psig (10 bar) 的输出,可满足更高压力的工业、气动和过程控制系统要求。 TYPE500X电气转换器_TYPE500-AC_TYPE500-AD电气比例阀_康气通controlair
|
||
---|---|---|
The Type 500X is available in two different versions. The lower range model is designed for standard process control applications which typically utilize a 3 to 15 psig output. The extended range unit provides up to 120 psig output for higher pressure industrial pneumatic and process control system requirements. Principle of Operation The Type 500X Transducer is a force balance device in which a coil is suspendedi n the field of a magnet by af lexure. Current flowing through the coil generates axial movement of the coil and flexure. The flexure moves towards the nozzle and creates back pressure which acts as a pilot pressure to an integral booster relay. Input signal increases (or decreases for reverse acting) cause proportional output pressure increases. Zero and Span are calibrated by turning adjust screws on the front face of the unit. Adjustment of the zero screw repositions the nozzle relative to the flexure. The span adjustment is a potentiometer that controls the amount of current through the coil. |
Mounting The Type 500X may be mounted by pipe, panel, or bracket. Field adjustment of the zero may be required if position is changed. High external vibration may cause output fluctuations. Mounting in a vibration-free area is recommended. Split Ranging If split ranging is required the 4-20 mA input, 3-15 psig output version (ControlAir part number 500-AC) can be recalibrated to provide a 3-9 psig or 9- 15 psig output. Intrinsically Safe The Type 500X has been tested and approved by Factory Mutual as Intrinsically Safe Class I, II, and III, Division 1, Groups C, D, E, F and G when used with an apparatus meeting the following entity requirements: Vmax = 29.9 V Cl = 0 Cl is capitance Imax = 65 mA Ll = 35 mH Ll is inductanceNEMA-4X (IP65) Enclosure Optional Factory Mutual NEMA 4X enclosure rating allows for installation in splashdown or outdoor environments. Unit also meets the requirements of IEC standards IP65. |
Installation should be in accordance with ControlAir interconnection drawing no. 431-990-013. This drawing is included in the Type 500X Installation, Operation and Maintenance Instruction. The Intrinsically Safe approval is a standard feature of the Type 500X and applies only to units with a 4-20 mA input signal that are installed with the following barriers: R.Stahl, Inc. barriers: MTL, Inc. barriers: 9001/01-280-100-10 728 9002/13-280-110-00 787S+ 4045 The Type 500X is also Factory Mutual Approved as Nonincendive for Class I, Division 2, Groups A, B, C and D, and suitable for Class II and III, Division 2, Group F and G. Barriers are not required for nonincendive rating. Field Reversible In the reverse acting mode the output is the opposite of the direct acting mode (i.e. 4-20 mA input creates a 15-3 psig output). To change from direct acting to reverse acting simply reverse the polarity of the signal leads and recalibrate. Input signal failure causes output pressure to reach maximum value (i.e. 15 psig) when reverse acting. |
康气通ControlAir Type 500 电气转换器(I/P, E/P))图纸资料说明:Type 500X Electropneumatic Transducer (I/P, E/P)Economical and ve The Type 500X is available in two different versions. The lower range model is designed for standard process control applications which typically utilize a 3 to 15 psig output. The extended range unit provides up to 120 psig output for higher pressure industrial pneumatic and process control system requirements. Principle of Operation The Type 500X Transducer is a force balance device in which a coil is suspended in the field of a magnet by a flexure. Current flowing through the coil generates axial movement of the coil and flexure. The flexure moves towards the nozzle and creates back pressure which acts as a pilot pressure to an integral booster relay. Input signal increases (or decreases for reverse acting) cause proportional output pressure increases. Zero and Span are calibrated by turning adjust screws on the front face of the unit. Adjustment of the zero screw repositions the nozzle relative to the flexure. The span adjustment is a potentiometer that controls the amount of current through the coil. NEMA-4X (IP65) Enclosure Optional Factory Mutual NEMA 4X enclosure rating allows for installation in splashdown or outdoor environments. Unit also meets the requirements of IEC standards IP65. Conduit connection on
|
![]() |
![]() |
![]() |
---|---|---|
![]() |
||
|